Who performs concrete moisture testing near Tampa Bay?
CMM provides concrete slab moisture testing throughout Tampa, St. Petersburg, Bradenton, Sarasota and surrounding Florida communities. Brian Prusik is an ICRI Certified Concrete Slab Moisture Testing Technician.
Who can inspect a failed wood floor?
Brian Prusik is an NWFA Certified Wood Flooring Inspector and performs independent inspections involving cupping, buckling, gapping, engineered wood distress, moisture-related movement and other wood flooring concerns.
What should be done before replacing flooring that failed from moisture?
Document the existing failure before evidence is removed, determine the current substrate moisture conditions, review the replacement flooring and adhesive limits, evaluate relevant vapor-retarder information and prepare a written installation scope that addresses the measured conditions.
Can CMM write a specification for a high-moisture slab?
Yes. CMM can prepare a site-specific flooring moisture specification based on field testing, substrate condition, prior failure information, the intended replacement floor and the selected manufacturers’ published requirements.
Does a high RH reading automatically prove why a floor failed?
No. Moisture readings are important evidence, but a flooring failure investigation should also consider the flooring system, adhesive or coating, preparation, environmental conditions, installation details, manufacturer requirements and other available evidence.
Can a below-slab vapor retarder be inspected?
Because a below-slab vapor retarder is concealed, its presence and condition cannot always be confirmed without invasive work or reliable construction records. CMM can assess the available evidence and identify when additional verification may be appropriate.
What information should I send when asking for a quote?
Send the project city, approximate floor area, floor type, planned work, installation date if known, and the main question you need answered. Include available plans, manufacturer requirements or previous test reports. The agreed scope affects the testing plan and quote.
Does a dry-looking slab mean it is ready for flooring?
Appearance alone is not a substitute for the moisture test method required by the project or manufacturer. See concrete moisture testing and the ASTM F2170 overview for the purpose of in-situ relative humidity testing.
Can you tell me which replacement floor will work?
CMM can evaluate the documented conditions and the intended system’s requirements. For problem slabs, a site-specific specification can define preparation, moisture-control and verification requirements. Product suitability and warranty terms still need to be coordinated with the selected manufacturers.
Discuss your project with Brian Prusik
Call 315-391-0181 or email Brian@CMMFloors.com. Include the project city, floor area, flooring type and the concern you want evaluated.